SHOP FOR

Detax Implant Mask Standard Pack Addition Curing Special Silicone

₹2,820.0

100 item left in Stock

Description of product

Addition curing special silicone for manufacturing flexible gingival masks for implant procedures. Free-flowing, dimensionally stable, tear-resistant.

Flows evenly around impression coping with freeflowing properties. Very high elasticity allows repositioning as required. Very easily milled with high final hardness, approx. 70 Shore A.

INDICATIONS:

  • Implant constructions
  • Combination technique
  • Master and saw models
Features
  • Smoothly flowing
  • Tear-resistant
  • Dimensional stability
  • Even flow around the impression posts due to high flowability
  • Mini-mix hand cartridges for direct application without mixing gun
  • Outstanding reproduction
  • Very good processing due to high final hardness.
Key Specifications

Mixing ratio: 1:1

Working time: approx. 2 min.

Setting time: approx. 5 - 6 min.

Recovery from deformation: > 99%

Linear dimensional change: < 0.3%

Application: at 23° C ± 2° C/ 73° F ± 4° F, 50 ± 5 % rel. humidity

Storage:

  

Packaging
  • 2 x 10ml Cartridges Mini-Mix 1:1
  • 6 x Mixing Cannulas, Light Green 1:1
  • 1 x 15ml Separating Liquid for Silicones,Vaporizer
Direction to Use

1. Preparation

a) Fabrication by direct method, application to impression

Mark the edge of the gingival areas for the impression with soft wax or similar. Then insulate this area by spraying lightly with silicone Separating Agent. Drying time 30 sec. Silicone Separating Agent is suitable for A- and C-silicones and polyether impression material.
For the application of Implant Mask / scan with the mini-mix cartridge, always use a mixer with a fine tip. Inject directly around the impression or transfer posts and leave the tip of the mixer in the material during dispensing (Fig. 1). Dispense with steady pressure. Ensure that the Implant Mask / scan has the desired dimensions.Continue model fabrication only after the Implant Mask / scan has set completely (Fig. 2). Any separating medium residues on the laboratory posts can be removed with isopropyl alcohol. Insulation of the mask against plaster or resins is not necessary.
b) Fabrication by indirect method, on the model

To fabricate the Implant Mask / scan first make a silicone mould of addition- or condensation curing putty (e.g. blue eco or compact lab putty), which covers all of the areas of the unsawn model to be reproduced (Fig. 3). An available impression can be used as mould after removing the tray. Remove any areas in the index or impression that are in the way outside the gingival mask region so that it can be repositioned easily on the model.
Reduce the regions of the model that are to be reproduced by Implant Mask / scan by milling (Fig. 4). Take care to remove enough material to ensure the later thickness of the mask. Sawing and working the dies can take place before or after mask fabrication depending on the situation. If sawing is performed beforehand, block out the saw cuts.
Drill one or more injection openings (palatal/lingual) in the silicone. Drill air vent channels through the mould with a round bur starting from the highest points of the mask (Fig. 5), clean the mould and insulate it on the inside by spraying lightly with silicone Separating Agent. Drying time 30 sec. Put the mould back on the model,check that it is seated exactly and fix it.
Inject material quickly through the injection opening of the mould with the mini-mix cartridge (Fig. 6). Inspection: air vent channels must be filled with silicone. Demould the mask only after complete setting. Setting can take place in the pressure pot under pressure (max. 2.5 bar), not in water and without the addition of heat.

2. Mixing and applying

The material is extruded with the mini-mix system. Place the plunger in the body of the cartridge. Remove the cartridge cap by twisting off. Before attaching the mixing cannula extrude a small amount of material until silicone is dispensed evenly from the two openings (Fig. 7).
To attach the mixing cannula, note the guides on the cannula and cartridge. Lock by turning them in opposite directions (Fig. 8). Feed material applying even pressure.
Prior to use, dispense a small amount of material and visually check that the base and catalyst paste are mixed homogeneously (Fig. 9). Only then dosing can be performed individually.

3. Processing

When the mask has been fabricated on the model, remove the mould carefully from the model, trim any casting residues from the air vents with a scalpel and remove the mask. Remove any flash with a scalpel or sharp scissors.Further processing of the removed mask is possible with suitable rotating tools (Fig. 10)(Molloplast cutters, grinding sleeves with 15,000 - 25,000 r.p.m., tungsten carbide drills and arbors).

User reviews

  0/5